    HMO fire safety in London: what licensing actually requires

    What a licensing officer will actually check, and why the wrong alarm grade is the most common HMO failure we see across London boroughs.

    11 min readBy Nabhan Islam Reviewed by Awais Sarwar, MSc Updated 6 Sept 2026
    HMO fire safety in London: what licensing actually requires
    AudiKiaGB NewsBudgens
    The short answer

    HMO fire safety in London is judged primarily against LACORS guidance, which sets recommended fire detection, fire door and escape route standards based on the number of storeys and occupants, alongside the general duties in the Fire Safety Order 2005 and the licensing conditions set by each borough. Most licensed HMOs need an LD2 category fire alarm system as a minimum, 30-minute fire doors to all habitable rooms opening onto the escape route, and a fire risk assessment specific to the property. Getting any one of these wrong is the most common reason we see licence applications and renewals stall.

    020 3951 4856

    Minimum alarm grade

    LD2 (BS 5839-6)

    mains-wired, interlinked, for most licensed HMOs

    Fire door standard

    FD30S

    self-closing, 30-minute rated, to habitable rooms

    Mandatory licensing threshold

    5+ occupants, 2+ households

    regardless of storeys

    HMO assessment cost band

    from £180

    single converted property, typical London terrace

    Why HMOs are treated differently from other blocks

    A house in multiple occupation concentrates unrelated households sharing a single escape route, often in a converted building never designed for that use, with residents who may not know each other's habits, work patterns or the layout of the building. Where a purpose-built block of flats usually has each household behind its own fire-resisting front door, an HMO frequently has bedrooms opening straight onto a shared landing with a single staircase serving everyone. That difference in risk profile is exactly why licensing exists as a separate regime from the general duties on landlords, and why London boroughs inspect HMOs more closely and more often than most other residential stock. LACORS (the Local Authorities Coordinators of Regulatory Services) guidance, published following extensive work with fire and rescue services around the country, remains the reference document most London boroughs use to judge licence applications and renewals, even though it predates more recent legislation such as the Fire Safety Order and the Fire Safety Act 2021. It sits alongside, not instead of, that legislation, and in our experience it is still the document licensing officers physically bring to an inspection.

    How LACORS grades risk by building type

    LACORS does not apply a single blanket standard to every HMO — it uses a risk-based matrix that considers the number of storeys, whether the building has a basement or loft conversion in use, the total number of occupants, and how the kitchen and cooking facilities are arranged relative to escape routes. A small two-storey house with three sharers in a good layout is treated differently from a five-storey Victorian conversion with a basement flat and eight tenants, even though both might technically be an HMO.

    • Number of storeys served by the common escape route, including basements and converted lofts.
    • Total number of occupants and households, which drives both licensing thresholds and alarm category.
    • Whether cooking facilities are shared or self-contained within each letting.
    • Travel distance from the furthest bedroom door to the final exit.
    • Whether the building has a single stair or an alternative means of escape.
    • Any history of unauthorised alterations, such as stud walls added to create extra lettings.

    Alarm and detection standards

    LACORS grades required detection by the number of storeys and the layout, but in practice most licensed HMOs in London need at least an LD2 category system under BS 5839-6: mains-wired, interlinked smoke and heat detectors in circulation areas and higher-risk rooms, with battery back-up so the system still functions during a power cut. This is consistently the single biggest gap we find between what a landlord has fitted and what licensing actually expects, particularly in properties converted some years ago where the alarm has never been upgraded to reflect the current occupancy.

    • Interlinked smoke detectors in all circulation spaces (hallways, landings, stairwells).
    • Heat detectors, not smoke detectors, in kitchens to avoid nuisance alarms from cooking.
    • Smoke detectors in individual bedrooms/bedsits in higher-risk layouts (three or more storeys, or larger HMOs).
    • A control panel with zone indication for larger properties so a fault or activation can be located quickly by whoever attends.
    • Weekly test and periodic servicing records kept on site or accessible to the licensing officer.
    • Battery back-up on every device so the system continues to function through a mains failure.

    The buildings behind this advice

    AudiKiaGB NewsBudgensPepe's Piri PiriCar Giant

    Fire doors and escape routes in converted properties

    Converted HMOs are frequently older buildings retrofitted for multi-occupation, which is where most fire door and compartmentation issues arise — original lath-and-plaster ceilings, timber stud partitions and old staircases were not built with 30-minute separation in mind, and decades of subsequent alterations by different owners have often quietly undermined whatever separation did exist. We regularly find bedroom doors that look like fire doors but have no certification, closers that have been removed because tenants found them inconvenient, and gaps around frames well outside tolerance.

    • 30-minute (FD30) fire doors, self-closing, to all habitable rooms opening onto the common escape route.
    • Fire doors to any high-risk room such as a kitchen shared between households.
    • Escape route protected by fire-resisting construction where it passes through or alongside higher-risk rooms.
    • A single external final exit door usable without a key from inside at all times.
    • Emergency lighting on escape routes in larger or more complex HMOs, particularly where there are internal (borrowed light) routes.
    • Intumescent strips and cold smoke seals present and undamaged around the full perimeter of every fire door.

    What licensing officers actually check on inspection

    Borough licensing officers carry out physical inspections as part of both mandatory licensing (five or more people, two or more households sharing facilities) and additional or selective licensing schemes that many London boroughs now run, which can pull in smaller properties that would not otherwise need a licence. An officer's visit is not a paperwork exercise; they walk the building the same way an assessor does, testing doors, checking alarm panels and looking for evidence of what is actually happening day to day rather than what is written down.

    • Alarm system category and evidence of servicing and testing, usually via a logbook kept on site.
    • Fire door condition, closers, seals and any unauthorised alterations to doors or frames.
    • Escape route clearance and final exit door operation, tested by hand where possible.
    • Kitchen facilities relative to occupant numbers (often a separate amenity standard, but frequently inspected at the same visit).
    • General management standards, including whether a written fire risk assessment for the specific property exists and is current.
    • Electrical safety certificate (EICR) and gas safety certificate where applicable, since both link directly to ignition risk.

    Common reasons HMO licence applications stall on fire safety

    In practice a small number of issues account for most delays and licence conditions attached by boroughs, and nearly all of them are things a landlord could have fixed before the inspection with a modest amount of preparation and cost. We see the same handful of problems repeatedly across very different boroughs and property types.

    • Alarm system installed to a domestic (Grade F, battery-only) standard rather than the LD2 mains-wired standard expected for shared housing.
    • Bedroom doors that are not fire-rated, or fire-rated doors without a functioning self-closer.
    • Kitchen doors missing entirely where the kitchen opens directly onto the escape route.
    • No written, property-specific fire risk assessment — a generic template for a different building is not sufficient.
    • Storage or clutter in the means of escape at the time of inspection, from bikes to bins to boxed deliveries.
    • Loft or basement conversions used for sleeping accommodation without the corresponding upgrade to alarm coverage and escape provision.

    Before a licensing visit

    • Confirm alarm category matches storeys and occupancycheck the servicing certificate states the category, not just 'smoke alarms fitted'
    • Test every self-closer on habitable room and kitchen doorsshould close fully from any open angle on the first attempt
    • Clear all storage from corridors, landings and stairwellsbikes, buggies and boxes are the most common on-the-day failure
    • Have a property-specific fire risk assessment available on sitedated within the last 12 months and matching current occupancy
    • Check the final exit opens without a key from insideat any hour, for any resident

    Additional and selective licensing across London boroughs

    Many London boroughs run additional licensing schemes covering smaller HMOs that fall below the mandatory five-person threshold, and some run selective licensing across entire wards covering any rented property regardless of occupancy type. The fire safety standard expected under these schemes is broadly similar to mandatory licensing, but the thresholds and specific conditions vary noticeably between boroughs — a property just over a borough boundary can face a materially different set of requirements. Landlords with portfolios spanning more than one borough should never assume the conditions that applied in one authority automatically transfer to another.

    How this interacts with the wider Fire Safety Order duties

    Meeting borough licensing conditions and complying with the Fire Safety Order are related but not identical exercises — a property can technically meet licensing conditions at the point of inspection and still need updates to its fire risk assessment following a change of occupancy, added tenants, or a change in furniture and layout that happens months later. Licensing is periodic; the Fire Safety Order duty is continuous. Landlords running licensed HMOs should treat the licence conditions as a floor, and keep the fire risk assessment itself under regular review as the primary ongoing compliance document, updated whenever the property or its occupants change materially rather than only when a licence comes up for renewal.

    What we recommend before applying or renewing

    The most efficient route for most landlords is to commission a property-specific fire risk assessment before submitting or renewing a licence application, rather than waiting for the licensing officer's visit to surface problems. An assessment carried out by someone who understands both the Fire Safety Order and LACORS-based licensing expectations will flag alarm category mismatches, door defects and layout concerns in a single visit, with a prioritised action list that distinguishes urgent fixes from longer-term improvements — which is far cheaper than a failed inspection, a delayed licence, or a licence granted with conditions that then need re-inspecting.

    Written by

    Nabhan Islam

    Head of Marketing & Commercial Lead

    Reviewed by

    Awais Sarwar, MSc

    Fire Risk Assessor — IFSM-registered, National Fire Risk Assessor Register ID 1576

    11 min readLast reviewed 6 September 2026Facts verified 6 September 2026 Checked quarterly

    Sources

    1. Regulatory Reform (Fire Safety) Order 2005 legislation.gov.uk
    2. Fire safety risk assessment guidance GOV.UK (Home Office)
    3. Housing Act 2004 (HMO licensing and HHSRS) legislation.gov.uk
    4. House in multiple occupation licence GOV.UK
    5. London Fire Brigade fire safety guidance London Fire Brigade

    Was this page helpful?

    Frequently asked questions

    Call
    Last word

    Ready when you are.

    Quote in 60 seconds. Assessor on site this week. Compliant report in your inbox within 24 hours. That's the whole process.

    020 3951 4856
    Transparent pricing No obligation 1,000+ assessments 100% compliance guarantee
    Awais Sarwar
    — Awais Sarwar, MSc
    MD · 4.9 Google
    4.9 rated
    ·1,000+ done·
    Guaranteed
    Call